SkyBoys (Hangzhou) Technology Co., Ltd. is pleased to present our high-performance eco-friendly water-based fibreglass aerogel felt. This product not only meets stringent requirements for insulation, thermal protection and cushioning, but also fully complies with the highest environmental standards, including the EU’s RoHS and REACH regulations, making it the ideal choice for cutting-edge industrial and new energy sectors.

  • +8613626519690
  • +8613626519690
  • +8613626519690

1. Chemical Name

Chemical Name: Fiberglass Aerogel Felt

2. Product Model, Performance, and Specifications

The specifications and performance indicators of the fiberglass aerogel felt are listed in Table 1.

Product Model

XKNH-C

Thickness

0.5-20mm Customizable

Dimensions

Sheet / Customizable

Colors

White

Maximum operating

temperature

1200℃

Density

200±20kg/m3

Thermal conductivity

25℃ ≤ 0.021 W/m·K

GB/T 10295-2008

100℃ ≤ 0.022 W/m·K

 

300℃ ≤ 0.036 W/m·K

 

300℃ ≤ 0.036 W/m·K

W/m·K

 

Flame Retardant Rating

UL94-V0/5VA

UL 94-2013

Hydrophobic Properties

≥99.3%

GB/T 10299-2011

Insulation Properties

1000V (DC), 60s, electrical insulation resistance ≥ 500MΩ

GB/T 10064—2006

Pressure Resistance

2.7kV, 60s, no breakdown jump fire, leakage current ≤0.1mA

GB/T 1408. 1-2016

Compression Performance

2MPa Compression rate 15-30%

(Can be adjusted according to the compression performance of the encapsulated product)

GB/T 13480-2014

Halogens

Halogen-free

EN 14582:2016

RoHS

Complies with the restrictions of the EU RoHS Directive

Directive (EU) 2015/863 amending Appendix II of 2011/65/EU

REACH

224 Substances of Very High Concern SVHC test results <0.1% (w/w)

REACH Regulation (EC) No. 1907/2006

Automotive Banned Substances

Compliance with automotive banned substance requirements

GB/T 30512-2014

Applications

Thermal insulation, flame retardance, and cushioning in new energy vehicle battery cells and modules

Petroleum and Petrochemical/Energy Storage/Aerospace/3C Electronics/Urban Heating/Power Cell/Building Materials

Table 1: Performance Specifications of Fiberglass Aerogel Felt

3. Composition and Chemical Information

Component

CAS No.

Content (by weight)

Amorphous SiO₂

7631-86-9

40–60%

Potassium silicate

65997-17-3

20–40%

Al₂O₃

1344-28-1

1–5%

 

4. Key Benefits Of Aluminum Film

  • Enhanced Thermal Performance: The aluminum foil reflects over 95% of infrared radiation, significantly reducing heat transfer.
  • Moisture and Vapor Barrier: Prevents water vapor penetration, protecting aerogel from moisture absorption and performance degradation.

  • Improved Durability & Weather Resistance: Resists UV, chemical corrosion, and salt spray for longer service life in harsh environments.

  • Surface Strength & Safety: Smooth, durable surface reduces dust release during installation and handling.

  • Superior Fire Resistance: Aluminum is non-combustible, providing an extra layer of fire protection.

5. Applications

  • Building Exterior Insulation

Ideal for high-temperature, high-humidity, and energy-saving wall systems.

  • Industrial Pipeline Insulation

Suitable for oil, chemical, and gas pipelines, reducing heat loss and providing safety protection.

  • Energy Storage Systems

Used in battery cabinets and compartments to prevent thermal runaway and block external heat sources.

  • Cold Chain Transportation

Applied in refrigerated truck doors and walls to minimize cooling loss and prevent condensation.

  • Marine & Offshore Equipment

Protects against moisture, corrosion, and heat in marine environments.

6. Performance Characteristics

  • High compactness:

Lightweight material that withstands high pressure; suitable for transportation, installation, and matching various load-bearing conditions.

  • Excellent thermal insulation:

Same insulation performance at reduced thickness compared to traditional insulation, offering more space and efficient utilization.

  • Flame resistance: Excellent fire resistance.
  • Good adhesion:

Strong bonding with various substrates; stable even under moisture and temperature fluctuations.

  • Non-combustible & Safe:

No harmful emissions when exposed to open flame or high temperatures, with high safety and reliability.

  • Non-toxic: Harmless to humans and the environment.

 

7. Product Quality Inspection Specifications

  • Testing Conditions

Unless otherwise specified, testing conditions are:
Temperature: (23 ± 2)℃
Relative humidity: (50 ± 5)%

  • Sampling Method

Sampling according to prescribed methods.

  • Acceptance Criteria

If all inspected indicators meet the technical specifications, the product is deemed qualified.
If visual inspection or performance parameters do not meet the criteria, it shall be deemed unqualified.
Where appearance issues do not affect product performance and usage, such defects are permitted upon customer approval.

  • Test Methods

Test Methods: As per values in Table 1.

 

8. Delivery Preparation

  • Packaging and Labeling
  • Protective Packaging

Unless otherwise specified, each box of products must be packaged with soft protective cushioning materials to prevent damage.

  • Carton Packaging

Unless otherwise specified, the outer cartons shall be made of standard packaging materials such as corrugated cardboard boxes or tile paper boxes. The product arrangement inside the cartons must be neat and secure.

  • Inspection Report

Each batch of products must be accompanied by a performance inspection report.

  • The outer packaging must clearly indicate:
  1. Product name and model
  2. Specification and quantity
  3. Production date
  • Transportation and Storage

During transportation, products must be protected from compression and collision. They shall be stored in a clean, dry, and ventilated environment. Stacking should not exceed three layers.

 

9. Remarks

  • Intended Use

The product can be used for electrical insulation, heat insulation, and maintenance purposes.

  • Certificate of Conformity

Each batch must be accompanied by a Certificate of Conformity, which includes:

  1. Manufacturer name and address
  2. Product name and model
  3. Specification and quantity
  4. Production date
  5. Inspector signature
  6. Packaging list