Aerogel Glass Fiber Heat Insulation Blanket

1. Product description

Chemical Name: Fiberglass Aerogel Felt

Thermal insulation, fireproof, waterproof soundproofing layer for multi-layer wall structures.

2. Product Model, Performance, and Specifications

The specifications and performance indicators of the fiberglass aerogel felt are listed in Table 1.

Product ModelXKNH-C
LengthCustomizable
Width20-1500mm Customizable
Thickness0.5-20mm Customizable
DimensionsSheet / Felt Customizable
ColorsWhite
Maximum operatingtemperature1200℃
Density200±20kg/m3
Thermal conductivity25℃ ≤ 0.021 W/m·KGB/T 10295-2008
100℃ ≤ 0.022 W/m·K 
300℃ ≤ 0.036 W/m·K 
300℃ ≤ 0.036 W/m·KW/m·K 
Flame Retardant RatingUL94-V0/5VAUL 94-2013
Hydrophobic Properties≥99.3%GB/T 10299-2011
Insulation Properties1000V (DC), 60s, electrical insulation resistance ≥ 500MΩGB/T 10064—2006
Pressure Resistance2.7kV, 60s, no breakdown jump fire, leakage current ≤0.1mAGB/T 1408. 1-2016
Compression Performance2MPa Compression rate 15-30%(Can be adjusted according to the compression performance of the encapsulated product)GB/T 13480-2014
HalogensHalogen-freeEN 14582:2016
RoHSComplies with the restrictions of the EU RoHS DirectiveDirective (EU) 2015/863 amending Appendix II of 2011/65/EU
REACH224 Substances of Very High Concern SVHC test results <0.1% (w/w)REACH Regulation (EC) No. 1907/2006
Automotive Banned SubstancesCompliance with automotive banned substance requirementsGB/T 30512-2014
ApplicationsThermal insulation, flame retardance, and cushioning in new energy vehicle battery cells and modulesPetroleum and Petrochemical/Energy Storage/Aerospace/3C Electronics/Urban Heating/Power Cell/Building Materials

Table 1: Performance Specifications of Fiberglass Aerogel Felt

 

3. Composition and Chemical Information

ComponentCAS No.Content (by weight)
Amorphous SiO₂7631-86-940–60%
Potassium silicate65997-17-320–40%
Al₂O₃1344-28-11–5%

4. Applications

  1. Building Exterior Insulation

Ideal for high-temperature, high-humidity, and energy-saving wall systems.

  • Industrial Pipeline Insulation

Suitable for oil, chemical, and gas pipelines, reducing heat loss and providing safety protection.

  • Energy Storage Systems

Used in battery cabinets and compartments to prevent thermal runaway and block external heat sources.

  • Cold Chain Transportation

Applied in refrigerated truck doors and walls to minimize cooling loss and prevent condensation.

  • Marine & Offshore Equipment

Protects against moisture, corrosion, and heat in marine environments.

5. Performance Characteristics

  1. High compactness:

Lightweight material that withstands high pressure; suitable for transportation, installation, and matching various load-bearing conditions.

  • Excellent thermal insulation:

Same insulation performance at reduced thickness compared to traditional insulation, offering more space and efficient utilization.

Compared to traditional rock wool materials, it achieves the same thermal insulation effect with half the thickness, significantly saving space.Flame resistance: Excellent fire resistance.

  • Good adhesion:

Strong bonding with various substrates; stable even under moisture and temperature fluctuations.

  • Non-combustible & Safe:

No harmful emissions when exposed to open flame or high temperatures, with high safety and reliability.

  • Non-toxic: Harmless to humans and the environment. Inorganic materials.

6. Product Quality Inspection Specifications

  1.  Testing Conditions

Unless otherwise specified, testing conditions are:
Temperature: (23 ± 2)℃
Relative humidity: (50 ± 5)%

  1.  Sampling Method

Sampling according to prescribed methods.

  1.  Acceptance Criteria

If all inspected indicators meet the technical specifications, the product is deemed qualified.
If visual inspection or performance parameters do not meet the criteria, it shall be deemed unqualified.
Where appearance issues do not affect product performance and usage, such defects are permitted upon customer approval.

  1. Test Methods

Test Methods: As per values in Table 1.

  1. Shelf life

120 Months.

7. Delivery Preparation

  1. Packaging and Labeling
    1. Protective Packaging

Unless otherwise specified, each box of products must be packaged with soft protective cushioning materials to prevent damage.

  1. Carton Packaging

Unless otherwise specified, the outer cartons shall be made of standard packaging materials such as corrugated cardboard boxes or tile paper boxes. The product arrangement inside the cartons must be neat and secure.

  1. Inspection Report

Each batch of products must be accompanied by a performance inspection report.

  1. The outer packaging must clearly indicate:
  2. Product name and model
  3. Specification and quantity
  4. Production date
    1. Transportation and Storage

During transportation, products must be protected from compression and collision. They shall be stored in a clean, dry, and ventilated environment. Stacking should not exceed three layers.

8. Remarks

  1. Intended Use

The product can be used for electrical insulation, heat insulation, and maintenance purposes.

  1. Certificate of Conformity

Each batch must be accompanied by a Certificate of Conformity, which includes:

HS Code:5602900000

Manufacturer name and address

Product name and model

Specification and quantity

Production date

Inspector signature

Packaging list